1.
Int Arch Otorhinolaryngol ; 28(2): e219-e225, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618593

RESUMO

Introduction Cochlear implant (CI) activation usually takes place at ∼ 30 days postoperative (PO). In our service, CI surgery is performed with local anesthesia and sedation, so activation is possible with the patient's cooperation, immediately after the CI surgery, still in the operating room (OR). Objective The objective of the present study was to provide the patient with hearing experience with the CI and to assess auditory perception immediately after surgery while still in the OR, as well as to compare impedance telemetry (IT), neural response telemetry (NRT), and comfort (C) level at two moments: in the OR and at the definitive activation, ∼ 30 days PO. Methods Nine adult patients (12 ears) with acquired (postlingual) deafness were included. Auditory perception was evaluated through the Ling Six Sound Check, musical instruments, and clapping, presented in two different programming maps, elaborated using t-NRT, and comparing IT, NRT, and C level between the two moments. Results We observed that while still in the OR, the patient can already present auditory detection and recognition responses. The values of IT, NRT threshold (t-NRT), and C on both dates differed, with statistical significance. Conclusion We concluded that it is possible to provide the patient with an auditory experience with the CI immediately after surgery, and that the auditory experience and the values of electrode IT, NRT, and C vary significantly between the two moments.

2.
Cochlear Implants Int ; 23(4): 232-240, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35337245

RESUMO

INTRODUCTION: Cochlear implants allow measures of neural function, through Neural response telemetry (NRT) and Auditory nerve recovery function (REC). These help in programming the speech processor and understanding the auditory system. However, not many studies have evaluated and compared these in different regions of the cochlea. OBJECTIVE: Comparing NRT and REC in different regions of the cochlea. METHODS: Cross-sectional, descriptive and prospective. NRT and REC (through the function of T0 - absolute refractory period, A - amplitude and TAU - time constant of the relative refractory period parameters) were evaluated, in three groups according to the stimulated electrode of the cochlea: apical, medial and basal. RESULTS: 26 adult patients were evaluated, 2 bilateral, totalling 28 ears. Data analysis showed no statistically significant difference between NRT between medial and basal but showed between apical and medial and apical and basal. For T0, there was a significant difference between medial and basal; for A, there was a significant difference between apical and basal and also medial and basal; and for TAU, there was no significant difference. CONCLUSION: There was a statistically significant difference in NRT and REC when compared between different regions of the cochlea.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Cóclea/cirurgia , Nervo Coclear/cirurgia , Estudos Transversais , Humanos , Estudos Prospectivos , Telemetria
3.
Eur Arch Otorhinolaryngol ; 278(8): 2823-2828, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32948894

RESUMO

PURPOSE: Refinement currently offered in new sound processors may improve noise listening capability reducing constant background noise and enhancing listening in challenging signal-to-noise conditions. This study aimed to identify whether the new version of speech processor preprocessing strategy contributes to speech recognition in background noise compared to the previous generation processor. METHODS: This was a multicentric prospective cross-sectional study. Post-lingually deaf adult patients, with at least 1 year of device use and speech recognition scores above 60% on HINT sentences in quiet were invited. Speech recognition performance in quiet and in noise with sound processors with previous and recent technologies was assessed under four conditions with speech coming from the front: (a) quiet (b) fixed noise coming from the front, (c) fixed noise coming from the back, and (d) adaptive noise ratios with noise coming from the front. RESULTS: Forty-seven cochlear implant users were included. No significant difference was found in quiet condition. Performance with the new processor was statistically better than the previous sound processor in all three noisy conditions (p < 0.05). With fixed noise coming from the back condition, speech recognition was 62.9% with the previous technology and 73.5% on the new one (p < 0.05). The mean speech recognition in noise was also statistically higher, with 5.8 dB and 7.1 dB for the newer and older technologies (p < 0.05), respectively. CONCLUSION: New technology has shown to provide benefits regarding speech recognition in noise. In addition, the new background noise reduction technology, has shown to be effective and improves speech recognition in situations of more intense noise coming from behind.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Estudos Transversais , Humanos , Estudos Prospectivos , Fala
4.
Int. arch. otorhinolaryngol. (Impr.) ; 24(4): 444-449, Oct.-Dec. 2020. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1134177

RESUMO

Abstract Introduction Cochlear implants (CIs) enable objective measures of the neural function in implanted patients through the measurements of the neural response telemetry (NRT) and of the Auditory nerve Recovery Function (REC). These measurements help in programming the speech processor and understanding the auditory system. Objective To compare the NRT and the REC in prelingual and postlingual implanted patients. Methods An observational, descriptive and prospective study was carried out. The NRT and the REC (through the T0, A, and tau parameters) were evaluated in individuals submitted to CI surgery, who were divided into two groups: prelingual and postlingual patients. Results In total, 46 patients were evaluated. Data analysis showed no statistically significant difference between the NRT measurements and the T0, A, and Tau of the REC in the comparison between the two groups, except for the NRT in the basal cochlear region. Conclusion There was no statistically significant difference in the REC in pre- and postlingual patients.

5.
Int Arch Otorhinolaryngol ; 24(4): e444-e449, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33101509

RESUMO

Introduction Cochlear implants (CIs) enable objective measures of the neural function in implanted patients through the measurements of the neural response telemetry (NRT) and of the Auditory nerve Recovery Function (REC). These measurements help in programming the speech processor and understanding the auditory system. Objective To compare the NRT and the REC in prelingual and postlingual implanted patients. Methods An observational, descriptive and prospective study was carried out. The NRT and the REC (through the T0, A, and tau parameters) were evaluated in individuals submitted to CI surgery, who were divided into two groups: prelingual and postlingual patients. Results In total, 46 patients were evaluated. Data analysis showed no statistically significant difference between the NRT measurements and the T0, A, and Tau of the REC in the comparison between the two groups, except for the NRT in the basal cochlear region. Conclusion There was no statistically significant difference in the REC in pre- and postlingual patients.

6.
Int. arch. otorhinolaryngol. (Impr.) ; 24(1): 11-17, Jan.-Mar. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1090557

RESUMO

Abstract Introduction Local anesthesia with sedation has been employed for an increasingly number of otolaryngology procedures, and might be associated with lower surgical morbidity and costs. Facial nerve monitoring is often advisable in otology to minimize the risks of injuries to this cranial nerve, but the principles, techniques and parameters involved have only been studied for procedures under general anesthesia. Objective To report the preliminary outcomes of intraoperative facial nerve moni- toring during otologic procedures under sedation and local anesthesia. Methods A total of five procedures and their respective intraoperative electrophysi- ological main findings were described. Facial neuromonitoring was performed using the same device by an electrophysiologist. The monitor sensitivity was set at 100 mV, and a stimulating probe was used whenever needed. Results Progressively decreasing low-amplitude baseline values were usually obtained as the level of anesthesia increased, with isolated oscillations possibly related to some degree of voluntary muscular activity. These oscillations could be easily distinguished from those of the surgical manipulation or electrical stimulation of the nerve, which tended to be of much greater amplitude and shorter latency, occurring during specific surgical steps. Conclusion With a surgical team with proper procedural knowledge and broad expertise regarding the technique, intraoperative facial nerve monitoring under local anesthesia with sedation seemed both feasible and reliable. Thus, the need for intraoperative neuromonitoring should not be an obstacle for otologic procedures under less aggressive anesthetic management.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Procedimentos Cirúrgicos Otológicos/métodos , Monitorização Intraoperatória/métodos , Nervo Facial/fisiologia , Anestesia Local , Resultado do Tratamento , Estimulação Elétrica , Eletromiografia
7.
Int Arch Otorhinolaryngol ; 24(1): e11-e17, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31929830

RESUMO

Introduction Local anesthesia with sedation has been employed for an increasingly number of otolaryngology procedures, and might be associated with lower surgical morbidity and costs. Facial nerve monitoring is often advisable in otology to minimize the risks of injuries to this cranial nerve, but the principles, techniques and parameters involved have only been studied for procedures under general anesthesia. Objective To report the preliminary outcomes of intraoperative facial nerve monitoring during otologic procedures under sedation and local anesthesia. Methods A total of five procedures and their respective intraoperative electrophysiological main findings were described. Facial neuromonitoring was performed using the same device by an electrophysiologist. The monitor sensitivity was set at 100 mV, and a stimulating probe was used whenever needed. Results Progressively decreasing low-amplitude baseline values were usually obtained as the level of anesthesia increased, with isolated oscillations possibly related to some degree of voluntary muscular activity. These oscillations could be easily distinguished from those of the surgical manipulation or electrical stimulation of the nerve, which tended to be of much greater amplitude and shorter latency, occurring during specific surgical steps. Conclusion With a surgical team with proper procedural knowledge and broad expertise regarding the technique, intraoperative facial nerve monitoring under local anesthesia with sedation seemed both feasible and reliable. Thus, the need for intraoperative neuromonitoring should not be an obstacle for otologic procedures under less aggressive anesthetic management.

8.
Braz. j. otorhinolaryngol. (Impr.) ; 85(4): 502-509, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019574

RESUMO

Abstract Introduction: The conventional evaluation of neural telemetry and impedance requires the use of the computer coupled to an interface, with software that provides visualization of the stimulus and response. Recently, a remote control (CR220®) was launched in the market, that allows the performance of intraoperative tests with minimal instrumentation. Objective: To evaluate the agreement of the impedance values and neural telemetry thresholds, and the time of performance in the conventional procedure and by the remote control. Methods: Multicentric prospective cross-sectional study. Intraoperative evaluations of cochlear implants compatible with the use of CR220® were included. The tests were carried out in the 22 electrodes to compare the time of performance in the two situations. The agreement of the neural telemetry threshold values obtained from five electrodes was analyzed, and the agreement of impedance was evaluated by the number of electrodes with altered values in each procedure. Results: There were no significant difference between the impedance values. There was a moderate to strong correlation between the electrically-evoked compound action potential thresholds. The mean time to perform the procedures using the CR220 was significantly lower than that with the conventional procedure. Conclusion: The use of the CR220 provided successful records for impedance telemetry and automatic neural response telemetry.


Resumo Introdução: A avaliação convencional da telemetria neural e de impedâncias implica o uso do computador acoplado a uma interface, o software fornece o estímulo e a visualização das respostas. Recentemente, foi lançado um controle remoto (CR220®), que possibilita testes intraoperatórios com instrumental mínimo. Objetivo: Avaliar a concordância dos valores das impedâncias e dos limiares da telemetria neural e o tempo de execução no procedimento convencional e pelo controle remoto. Método: Estudo prospectivo transversal multicêntrico. Foram incluídas as avaliações intraoperatórias de implante coclear compatível com o uso do CR220®. Os testes foram realizados nos 22 eletrodos para comparar os tempos de execução nas duas situações. Foi analisada a concordância dos valores do limiar da telemetria neural obtidos em cinco eletrodos e a concordância das impedâncias foi avaliada pelo número de eletrodos com valores alterados em cada procedimento. Resultados: Não houve diferença significante entre as impedâncias. Obteve-se moderada a forte correlação entre os limiares do potencial de ação composto eletricamente evocado. O tempo médio para os procedimentos com o CR220 foi significativamente menor do que com o procedimento convencional. Conclusão: O uso do CR220 proporcionou registros bem-sucedidos para a telemetria de impedância e a telemetria automática de respostas neurais.


Assuntos
Humanos , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Telemetria/instrumentação , Implantes Cocleares , Implante Coclear/instrumentação , Surdez/cirurgia , Limiar Auditivo , Testes de Impedância Acústica , Estudos Transversais , Estudos Prospectivos , Implante Coclear/métodos , Surdez/etiologia , Potenciais Evocados Auditivos
9.
Braz J Otorhinolaryngol ; 85(4): 502-509, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29858159

RESUMO

INTRODUCTION: The conventional evaluation of neural telemetry and impedance requires the use of the computer coupled to an interface, with software that provides visualization of the stimulus and response. Recently, a remote control (CR220®) was launched in the market, that allows the performance of intraoperative tests with minimal instrumentation. OBJECTIVE: To evaluate the agreement of the impedance values and neural telemetry thresholds, and the time of performance in the conventional procedure and by the remote control. METHODS: Multicentric prospective cross-sectional study. Intraoperative evaluations of cochlear implants compatible with the use of CR220® were included. The tests were carried out in the 22 electrodes to compare the time of performance in the two situations. The agreement of the neural telemetry threshold values obtained from five electrodes was analyzed, and the agreement of impedance was evaluated by the number of electrodes with altered values in each procedure. RESULTS: There were no significant difference between the impedance values. There was a moderate to strong correlation between the electrically-evoked compound action potential thresholds. The mean time to perform the procedures using the CR220 was significantly lower than that with the conventional procedure. CONCLUSION: The use of the CR220 provided successful records for impedance telemetry and automatic neural response telemetry.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Surdez/cirurgia , Telemetria/instrumentação , Testes de Impedância Acústica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Limiar Auditivo , Criança , Pré-Escolar , Implante Coclear/métodos , Estudos Transversais , Surdez/etiologia , Potenciais Evocados Auditivos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
10.
Ear Nose Throat J ; 97(9): E18-E22, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30273437

RESUMO

Recent studies have identified sensorineural hearing loss as a possible manifestation of ankylosing spondylitis. We conducted a study of 30 patients with ankylosing spondylitis to characterize their audiologic profile and to correlate their disease activity and functional indices with their hearing thresholds. The study group was made up of 18 men and 12 women, aged 25 to 58 years (mean: 46.5), who were diagnosed with ankylosing spondylitis. We compared their findings with a socially and demographically matched group of 30 healthy controls. All 60 participants underwent an audiologic assessment, consisting of pure-tone audiometry, speech audiometry, and tympanometry. We used validated indices to assess disease activity and functional status, and we compiled information on the time of diagnosis and the types of medications used to treat the ankylosing spondylitis. We found that the average of the mean air-conduction thresholds at 0.5, 1, 2, and 4 kHz in the ankylosing spondylitis group was significantly worse than that of the controls (p = 0.004). A statistically significant difference was observed at frequencies greater than 3 kHz (p < 0.05). A subgroup of case patients who used only a tumor necrosis factor-alpha inhibitor exhibited better hearing thresholds than patients who used other drugs (p = 0.01). Differences in functional and disease activity scores between case patients with and without hearing loss were not statistically significant. We found that patients with ankylosing spondylitis did indeed have a greater prevalence of sensorineural hearing loss but that it was not correlated with either disease activity or functional status.


Assuntos
Limiar Auditivo/fisiologia , Perda Auditiva Neurossensorial/etiologia , Espondilite Anquilosante/fisiopatologia , Adulto , Audiometria/métodos , Estudos de Casos e Controles , Feminino , Perda Auditiva Neurossensorial/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Espondilite Anquilosante/complicações , Espondilite Anquilosante/tratamento farmacológico , Fator de Necrose Tumoral alfa/antagonistas & inibidores
11.
Neurosurg Focus ; 44(3): E9, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29490548

RESUMO

Hearing loss is the most common symptom of vestibular schwannomas (VSs). The management of these lesions includes observation, radiosurgery, and microsurgical resection. Hearing preservation and rehabilitation are the major challenges after the tumor treatment. A 43-year-old man with previous left-sided profound hearing loss and tinnitus presented with a 2-mm left-sided intracanalicular VS. The decision was made to perform a simultaneous cochlear implantation (CI) and microsurgical resection of the tumor. The patient did well postoperatively, with significant improvement of tinnitus, sound localization, and speech recognition in noise. Previous reports of simultaneous CI and VS resection in patients with neurofibromatosis type 2 and sporadic VS in the only hearing ear have been described. The role of CI in patients with VS and normal contralateral hearing has been recently described, showing positive outcomes due to the binaural benefits. Tinnitus also can be treated by the implantation of the cochlear device. The simultaneous microsurgical removal of VS and implantation of a cochlear device is a feasible approach in patients with unilateral hearing loss and severe tinnitus.


Assuntos
Implante Coclear/métodos , Perda Auditiva/cirurgia , Neuroma Acústico/cirurgia , Procedimentos Neurocirúrgicos/métodos , Adulto , Perda Auditiva/diagnóstico por imagem , Perda Auditiva/etiologia , Humanos , Masculino , Neuroma Acústico/complicações , Neuroma Acústico/diagnóstico por imagem
12.
Audiol Neurootol ; 21(3): 150-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27161843

RESUMO

OBJECTIVE: To analyze auditory nerve recovery function (REC), comparing the results after local anesthesia and sedation with those after general anesthesia. METHODS: This was a prospective, cross-sectional and descriptive study in a tertiary referral center hospital. We included all patients (37 ears) who underwent surgery for cochlear implant under either general anesthesia or local anesthesia and sedation during 3 years. REC was measured according to the function of 3 components, 'T0', 'A' and 'tau', and was taken for 3 cochlear electrodes (apical, medial and basal). RESULTS: There were no significant differences in 'tau' and in the current level used, but there were significant differences in the parameters 'T0' apical and 'A' basal. CONCLUSIONS: There were no significant differences in REC between the 2 types of anesthesia, except for the parameters 'T0' apical and 'A' basal.


Assuntos
Anestesia Geral/métodos , Anestesia Local/métodos , Implante Coclear/métodos , Implantes Cocleares , Nervo Coclear/fisiopatologia , Sedação Consciente/métodos , Surdez/reabilitação , Recuperação de Função Fisiológica , Adolescente , Adulto , Cóclea , Nervo Coclear/fisiologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
13.
Med Probl Perform Art ; 31(1): 18-24, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26966960

RESUMO

OBJECTIVES: To evaluate voice improvement after phonosurgery by subjective and objective voice analysis. DESIGN: Prospective observational analytic group study. METHODS: This study was conducted from January 2012 to December 2013. Two hundred forty professional voice users (patients), classified as Koufman level I or II with benign vocal fold lesions, were divided in two groups. Patients in group 1 had a diagnosis of superficial vocal fold lesions, and patients in group 2 had deep lesions on the vocal folds. All patients completed the Vocal Performance Questionnaire (VPQ) and underwent acoustic voice tests using the Praat program. Subjective and objective voice analyses were performed before phonosurgery and at 1, 2, and 3 months after phonosurgery. A control group of 100 volunteers was created and underwent the same voice metrics that were applied to the patients. RESULTS: Jitter, shimmer, harmonic-to-noise ratio, and VPQ scores significantly differentiated patients with vocal fold lesions from individuals in the control group. All of the analyzed parameters improved significantly after phonosurgery. Additionally, patients with superficial vocal fold lesions achieved normal voice parameters 1 month after surgery, and patients with deep lesions achieved normal voice parameters 3 months after surgery. CONCLUSIONS: Analysis of vocal parameters using the VPQ and acoustic tests revealed voice improvement after phonosurgery for both patient groups.


Assuntos
Doenças da Laringe/cirurgia , Prega Vocal/cirurgia , Distúrbios da Voz/cirurgia , Qualidade da Voz , Treinamento da Voz , Adulto , Disfonia/etiologia , Disfonia/cirurgia , Feminino , Humanos , Doenças da Laringe/complicações , Doenças da Laringe/patologia , Masculino , Pessoa de Meia-Idade , Pólipos/patologia , Pólipos/cirurgia , Estudos Prospectivos , Prega Vocal/patologia , Distúrbios da Voz/etiologia , Adulto Jovem
14.
Int Arch Otorhinolaryngol ; 19(1): 10-5, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25992145

RESUMO

Introduction Neural response telemetry (NRT) is a method of capturing the action potential of the distal portion of the auditory nerve in cochlear implant (CI) users, using the CI itself to elicit and record the answers. In addition, it can also measure the recovery function of the auditory nerve (REC), that is, the refractory properties of the nerve. It is not clear in the literature whether the responses from adults are the same as those from children. Objective To compare the results of NRT and REC between adults and children undergoing CI surgery. Methods Cross-sectional, descriptive, and retrospective study of the results of NRT and REC for patients undergoing IC at our service. The NRT is assessed by the level of amplitude (microvolts) and REC as a function of three parameters: A (saturation level, in microvolts), t0 (absolute refractory period, in seconds), and tau (curve of the model function), measured in three electrodes (apical, medial, and basal). Results Fifty-two patients were evaluated with intraoperative NRT (26 adults and 26 children), and 24 with REC (12 adults and 12 children). No statistically significant difference was found between intraoperative responses of adults and children for NRT or for REC's three parameters, except for parameter A of the basal electrode. Conclusion The results of intraoperative NRT and REC were not different between adults and children, except for parameter A of the basal electrode.

15.
Int. arch. otorhinolaryngol. (Impr.) ; 19(1): 10-15, Jan-Mar/2015. tab
Artigo em Inglês | LILACS | ID: lil-741533

RESUMO

Introduction Neural response telemetry (NRT) is a method of capturing the action potential of the distal portion of the auditory nerve in cochlear implant (CI) users, using the CI itself to elicit and record the answers. In addition, it can alsomeasure the recovery function of the auditory nerve (REC), that is, the refractory properties of the nerve. It is not clear in the literature whether the responses from adults are the same as those from children. Objective To compare the results of NRT and REC between adults and children undergoing CI surgery. Methods Cross-sectional, descriptive, and retrospective study of the results of NRT and REC for patients undergoing IC at our service. The NRT is assessed by the level of amplitude (microvolts) and REC as a function of three parameters: A (saturation level, in microvolts), t0 (absolute refractory period, in seconds), and tau (curve of the model function), measured in three electrodes (apical, medial, and basal). Results Fifty-two patients were evaluated with intraoperative NRT (26 adults and 26 children), and 24 with REC (12 adults and 12 children). No statistically significant difference was found between intraoperative responses of adults and children for NRTor for REC's three parameters, except for parameter A of the basal electrode. Conclusion The results of intraoperative NRT and REC were not different between adults and children, except for parameter A of the basal electrode. .


Assuntos
Feminino , Humanos , Masculino , Ácido Ascórbico/farmacologia , Exercício Físico , Consumo de Oxigênio/efeitos dos fármacos , Resistência Física/efeitos dos fármacos , Vitamina E/farmacologia , Vitaminas/farmacologia
16.
Otol Neurotol ; 34(1): 75-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23187931

RESUMO

OBJECTIVES: The purpose of this study is to evaluate the possibility of performing cochlear implant surgery under local anesthesia and sedation and to evaluate the response of patients under sedation at the time of neural telemetry, comparing the differences with general anesthesia. PATIENTS: Twenty adult patients with bilateral sensorineural profound hearing loss submitted to cochlear implant surgery under general anesthesia and 20 patients under local anesthesia and intravenous sedation in the period from February 2011 to February 2012. The study was approved by the ethical committee of the institution. INTERVENTION: In both groups, we compared the costs of anesthesia, surgical time, time in recovery room, length of hospital stay, postoperative symptoms (pain, nausea, vomiting, and dizziness) and the degree of patient satisfaction. Besides, the reactions of the patients in the moment of the neural telemetry were also analyzed. MAIN OUTCOME MEASURES: The endpoint of this study is to establish the possibility of doing cochlear implant surgery with local anesthesia and sedation, discussing the differences and advantages over general anesthesia. RESULTS: By t-test variables, time in recovery room, time in hospital stay, and cost of inpatient anesthesia differ between groups, being always lower in the group of local anesthesia with sedation. The same result can be obtained using the Wilcoxon test. The symptoms of nausea, vomiting, and dizziness did not differ in the 2 groups. CONCLUSION: We conclude that the realization of the cochlear implant surgery under local anesthesia, and sedation is perfectly feasible with some advantages over general anesthesia. There were no problems during the neural telemetry performed by the time of the surgery in patients with local anesthesia with sedation.


Assuntos
Anestesia Geral , Anestesia Local , Implante Coclear/métodos , Perda Auditiva Neurossensorial/cirurgia , Adulto , Sedação Consciente , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente
17.
Braz J Otorhinolaryngol ; 78(4): 71-5, 2012.
Artigo em Inglês, Português | MEDLINE | ID: mdl-22936140

RESUMO

UNLABELLED: There are two techniques for cochlear implant (CI) electrode placement: cochleostomy and the round window (RW) approach. OBJECTIVE: This study aims to compare neural response telemetry (NRT) results immediately after surgery to check for possible differences on auditory nerve stimulation between these two techniques. MATERIALS AND METHODS: This is a prospective cross-sectional study. Twenty-three patients were enrolled. Six patients underwent surgery by cochleostomy and 17 had it through the RW approach. RESULTS: Mean charge units (MCU) for high frequency sounds: patients submitted to the RW approach had a mean value of 190.4 (± 29.2) while cochleostomy patients averaged 187.8 (± 32.7); p = 0.71. MCU for mid frequency sounds: patients submitted to the RW approach had a mean value of 192.5 (± 22) while cochleostomy patients averaged 178.5 (± 18.5); p = 0.23. MCU for low frequency sounds: patients submitted to the RW approach had a mean value of 183.3 (± 25) while cochleostomy patients averaged 163.8 (± 19.3); p = 0.19. CONCLUSION: This study showed no differences in the action potential of the distal portion of the auditory nerve in patients with multichannel cochlear implants submitted to surgery by cochleostomy or through the RW approach, using the implant itself to generate stimuli and record responses. Both techniques equally stimulate the cochlear nerve. Therefore, the choice of approach can be made based on the surgeon's own preference and experience.


Assuntos
Implante Coclear/métodos , Surdez/cirurgia , Janela da Cóclea/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Cóclea/cirurgia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Telemetria , Resultado do Tratamento , Adulto Jovem
18.
Braz. j. otorhinolaryngol. (Impr.) ; 78(4): 71-75, jul.-ago. 2012. tab
Artigo em Português | LILACS | ID: lil-646774

RESUMO

Existem duas técnicas para inserção dos eletrodos do implante coclear (IC): Via cocleostomia ou via janela redonda (JR). OBJETIVO: Comparar a telemetria de resposta neural (NRT) no pós-operatório imediato, verificando se há diferenças na estimulação do nervo auditivo entre estas duas técnicas. MÉTODOS: Prospectivo e transversal. Foram avaliados 23 pacientes. Seis submetidos à cirurgia via cocleostomia e 17 via JR. RESULTADOS: Comparação das unidades de corrente médias (UCM) para sons agudos: via JR com média de 190,4 (± 29,2) e via cocleostomia 187,8 (± 32,7), p = 0,71. Comparação das UCM para sons intermediários: via JR, média de 192,5 (± 22) e via cocleostomia 178,5 (± 18.5), p = 0,23. Comparação das UCM para sons graves: via JR, média de 183,3 (± 25) e via cocleostomia 163,8 (± 19,3), p = 0,19. CONCLUSÃO: Este estudo não mostrou diferença na captação do potencial de ação da porção distal do nervo auditivo em pacientes usuários do implante coclear multicanal submetidos à cirurgia via cocleostomia ou via JR, utilizando o próprio implante para eliciar o estímulo e gravar as respostas. Portanto, ambas as técnicas estimulam de maneira igual o nervo coclear, e baseado nisto conclui-se, também, que realizar o implante coclear via cocleostomia ou RW é uma escolha que depende da experiência cirúrgica e opção do cirurgião.


There are two techniques for cochlear implant (CI) electrode placement: cochleostomy and the round window (RW) approach. OBJECTIVE: This study aims to compare neural response telemetry (NRT) results immediately after surgery to check for possible differences on auditory nerve stimulation between these two techniques. MATERIALS AND METHODS: This is a prospective cross-sectional study. Twenty-three patients were enrolled. Six patients underwent surgery by cochleostomy and 17 had it through the RW approach. RESULTS: Mean charge units (MCU) for high frequency sounds: patients submitted to the RW approach had a mean value of 190.4 (± 29.2) while cochleostomy patients averaged 187.8 (± 32.7); p = 0.71. MCU for mid frequency sounds: patients submitted to the RW approach had a mean value of 192.5 (± 22) while cochleostomy patients averaged 178.5 (± 18.5); p = 0.23. MCU for low frequency sounds: patients submitted to the RW approach had a mean value of 183.3 (± 25) while cochleostomy patients averaged 163.8 (± 19.3); p = 0.19. CONCLUSION: This study showed no differences in the action potential of the distal portion of the auditory nerve in patients with multichannel cochlear implants submitted to surgery by cochleostomy or through the RW approach, using the implant itself to generate stimuli and record responses. Both techniques equally stimulate the cochlear nerve. Therefore, the choice of approach can be made based on the surgeon's own preference and experience.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Implante Coclear/métodos , Surdez/cirurgia , Janela da Cóclea/cirurgia , Estudos Transversais , Cóclea/cirurgia , Estudos Prospectivos , Telemetria , Resultado do Tratamento
19.
Braz J Otorhinolaryngol ; 78(3): 91-7, 2012 Jun.
Artigo em Inglês, Português | MEDLINE | ID: mdl-22714853

RESUMO

UNLABELLED: Learning disorders are often magnified by auditory processing disorders (APD). OBJECTIVE: This paper aims to verify whether individuals with reading and writing disorders and P300 latencies above the average also present altered Staggered Spondaic Word (SSW) and speech-in-noise test results suggestive of APD. MATERIALS AND METHODS: This is a cross-sectional cohort study. Twenty-one individuals with reading and writing disorders aged between 7 and 14 years were enrolled. RESULTS: All subjects had normal findings on ENT examination, audiological tests, and brainstem auditory evoked potentials. The average P300 latency (334,25 ms) of all patients was picked as a cutoff point to divide the subjects into two groups: group A with latencies above 335 ms, and group B with latencies below 335 ms. Individuals in group A underwent SSW and speech-in-noise testing. CONCLUSION: Altered results in the SSW and speech-in-noise tests suggestive of APD were found in the group of individuals with reading and writing disorders with P300 latencies above 335 ms.


Assuntos
Agrafia/fisiopatologia , Transtornos da Percepção Auditiva/diagnóstico , Potenciais Evocados P300/fisiologia , Potenciais Evocados Auditivos/fisiologia , Deficiências da Aprendizagem/etiologia , Adolescente , Transtornos da Percepção Auditiva/complicações , Transtornos da Percepção Auditiva/fisiopatologia , Criança , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Deficiências da Aprendizagem/fisiopatologia , Masculino , Leitura , Redação
20.
Braz. j. otorhinolaryngol. (Impr.) ; 78(3): 91-97, maio-jun. 2012. tab
Artigo em Português | LILACS | ID: lil-638588

RESUMO

As dificuldades na aprendizagem escolar muitas vezes podem ser causadas por uma alteração do Processamento Auditivo - PA. OBJETIVO: Identificar se acima da média dos valores de latência do P300, num grupo de indivíduos com Distúrbio de Leitura e Escrita, também seriam encontradas alterações no teste Staggered Spondaic Word - SSW e no teste de Fala no Ruído que sugerissem Desordem do Processamento Auditivo - DPA. MATERIAL E MÉTODOS: Estudo de coorte transversal. Foram avaliados 21 indivíduos com distúrbio de leitura e escrita, idade entre 7 e 14 anos. RESULTADOS: Todos apresentaram resultados normais no exame otorrinolaringológico, na avaliação audiológica e Potencial Evocado Auditivo de Tronco Encefálico. Fazendo-se a média aritmética de todos os valores de latência do P300 obtidos, chegou-se à média de 334,25 ms, sendo divididos em dois grupos: grupo "A", com média da latência acima de 335 ms, e "B", com latência abaixo de 335 ms. Nos indivíduos do grupo "A", foram realizados os testes SSW e Fala no Ruído. CONCLUSÃO:O presente estudo pode concluir que foram encontradas alterações nos testes de fala dicótica (SSW) e de Fala no Ruído no grupo de indivíduos com Distúrbio da Escrita e Leitura com valores de latência do P300 acima de 335 ms, sugerindo DPA.


Learning disorders are often magnified by auditory processing disorders (APD). OBJECTIVE: This paper aims to verify whether individuals with reading and writing disorders and P300 latencies above the average also present altered Staggered Spondaic Word (SSW) and speech-in-noise test results suggestive of APD. MATERIALS AND METHODS: This is a cross-sectional cohort study. Twenty-one individuals with reading and writing disorders aged between 7 and 14 years were enrolled. RESULTS: All subjects had normal findings on ENT examination, audiological tests, and brainstem auditory evoked potentials. The average P300 latency (334,25 ms) of all patients was picked as a cutoff point to divide the subjects into two groups: group A with latencies above 335 ms, and group B with latencies below 335 ms. Individuals in group A underwent SSW and speech-in-noise testing. CONCLUSION: Altered results in the SSW and speech-in-noise tests suggestive of APD were found in the group of individuals with reading and writing disorders with P300 latencies above 335 ms.


Assuntos
Adolescente , Criança , Feminino , Humanos , Masculino , Agrafia/fisiopatologia , Transtornos da Percepção Auditiva/diagnóstico , /fisiologia , Potenciais Evocados Auditivos/fisiologia , Deficiências da Aprendizagem/etiologia , Transtornos da Percepção Auditiva/complicações , Transtornos da Percepção Auditiva/fisiopatologia , Estudos de Coortes , Estudos Transversais , Deficiências da Aprendizagem/fisiopatologia , Leitura , Redação